UFC 400

Ultrasonic flow converter for combination with OPTISONIC 3000 and OPTISONIC 4000 flow sensors

  • Compact or remote field housing
  • With extensive diagnostics (NAMUR NE107) for advanced requirements
  • 4-wire, 3 x 4…20 mA, HART®7, FF, Profibus-PA/DP, Modbus etc.

UFC 400

Ultrasonic flow converter for combination with OPTISONIC 3000 and OPTISONIC 4000 flow sensors

  • Compact or remote field housing
  • With extensive diagnostics (NAMUR NE107) for advanced requirements
  • 4-wire, 3 x 4…20 mA, HART®7, FF, Profibus-PA/DP, Modbus etc.

Overview

The UFC 400 is a 4-wire ultrasonic signal converter. Combined with the flow sensors OPTISONIC 3000 and OPTISONIC 3000 District Heating it forms the OPTISONIC 3400 ultrasonic flowmeter for inline flow measurement of liquids as well as the OPTISONIC 3400 District Heating ultrasonic flowmeter for use in heat metering applications. Together with the OPTISONIC 4000 HT and HP flow sensors it forms the ultrasonic flowmeters OPTISONIC 4400 HT and OPTICONIC 4400 HP for inline flow measurement of high temperature and high pressure liquids.

Related products

OPTISONIC 3400

Ultrasonic flowmeter for liquid process applications

  • Accurate 3-path meter: large dynamic range, maintenance-free, no pressure loss
  • Cryogenic (-200°C/-328°F) and HT (+250°C/+482°F) versions; viscosities up to over 1000 cSt
  • Flange: DN25…3000 / 1…120", max. PN200 / ASME Cl 1500; also weld-ends
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP

OPTISONIC 3400 District Heating

Ultrasonic flowmeter for district heating applications

  • 3-path meter for thermal energy measurement and heated water
  • CT: OIML R75, MID MI-004 (Class 1, 2, 3)
  • Flange: DN25…2000 / 1…80", max. PN40 / ASME Cl 300
  • Max. +180°C / +356°F

OPTISONIC 4400 HP

Ultrasonic flowmeter for high pressure liquids

  • 2-path meter for flow measurement of condensate, high pressure feedwater, spray water or water injection
  • Operating pressure up to 490 bar / 7107 psi
  • Max. DN1000 / 40", up to ASME Cl 4500
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP

OPTISONIC 4400 HT

Ultrasonic flowmeter for high temperature liquids

  • 2-path meter for flow measurement of thermal oil, boiler feed water, crudes and hot feed flows in refineries
  • Up to +600°C / +1112°F
  • Flange: max. DN1000 / 40"
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP

OPTISONIC 3000

Ultrasonic flow sensor for combination with UFC 400 signal converter

  • Full bore design: pipe cross-section without restrictions
  • Connection sizes: DN25…3000 / 1…120"
  • Tube material: Carbon steel, stainless steel
Email
Contact